aboutsummaryrefslogtreecommitdiffhomepage
path: root/kauf-plug.yaml
diff options
context:
space:
mode:
Diffstat (limited to 'kauf-plug.yaml')
-rw-r--r--kauf-plug.yaml367
1 files changed, 254 insertions, 113 deletions
diff --git a/kauf-plug.yaml b/kauf-plug.yaml
index ee6e18f..c1daf04 100644
--- a/kauf-plug.yaml
+++ b/kauf-plug.yaml
@@ -2,8 +2,8 @@
substitutions:
# substitutions can be changed here if you are using this file directly in the ESPHome dashboard. The better approach is
- # to incorporate this file as a package using the following lines, and then overwrite these substitutions in your local
- # yaml file by redefining them.
+ # to incorporate this file as a package using the following packages: configuration, and then overwrite these substitutions
+ # in your local yaml file by redefining them.
#
# packages:
# kauf.plf10: github://bkaufx/PLF10/kauf-plug.yaml
@@ -15,7 +15,7 @@ substitutions:
# https://esphome.io/components/esphome.html#esphome-creators-project
project_name: Kauf.PLF10
- project_ver_num: "1.90"
+ project_ver_num: "1.91"
project_ver_let: y
# https://esphome.io/components/switch/gpio.html?highlight=restore_mode
@@ -31,7 +31,7 @@ substitutions:
sub_on_release_quick: script_do_nothing # executes when button is released after being held under 750ms
sub_on_release_short: script_do_nothing # executes when button is released after being held between 750ms and 5s
# For a longer hold, see kauf-plug-update.yaml in the config-update directory.
- # You have to start a time in the on_press script and cancel the timer in the on_release script.
+ # You have to start a timer in the on_press script and cancel the timer in the on_release script.
# or if you wanted to require release, then start a counter on press and check the value on release.
# If you want to have a hold action, you probably want to toggle on release_quick instead of on_press so that
# you can perform the hold action without toggling the plug's relay.
@@ -54,19 +54,21 @@ substitutions:
voltage_cal_val2_in: "302.1"
voltage_cal_val2_out: "117.1"
- # set power monitoring mode in yaml, selecting the "yaml_configured" option in the select entity will cause these values
- # to be used after next reboot.
+ # set power monitoring mode in yaml, selecting the "yaml_configured" option in the select entity will cause these
+ # values to be used after next reboot.
# https://esphome.io/components/sensor/hlw8012.html#configuration-variables
sub_change_mode_every: "1"
sub_update_interval: 10s
sub_initial_mode: CURRENT
+ # can be used to block status led from blinking
+ sub_blink_check: script_blink_check
# https://esphome.io/components/esp8266.html
esp8266:
board: esp01_1m
restore_from_flash: true
- start_free: 62
+ start_free: 74
global_addr: global_forced_addr
@@ -94,9 +96,36 @@ esphome:
on_boot:
priority: 700
then:
+
# priority 700 ensures power monitoring mode variables are changed
# in this script before HLW component is setup
- - script.execute: script_set_monitor_mode
+ # hlw_main will already have the YAML configured values by default, so
+ # no need to handle that here.
+ - lambda: |-
+
+ if ( id(select_monitor_mode).state == "10s P / 40s V,I") {
+ id(hlw_main)->set_update_interval(10000);
+ id(hlw_main)->set_change_mode_every(1); }
+
+ else if ( id(select_monitor_mode).state == "10s P,I Only" ) {
+ id(hlw_main)->set_update_interval(10000);
+ id(hlw_main)->set_change_mode_every(4294967295);
+ id(hlw_main)->set_initial_mode(hlw8012::HLW8012_INITIAL_MODE_CURRENT); }
+
+ else if ( id(select_monitor_mode).state == "10s P,V Only" ) {
+ id(hlw_main)->set_update_interval(10000);
+ id(hlw_main)->set_change_mode_every(4294967295);
+ id(hlw_main)->set_initial_mode(hlw8012::HLW8012_INITIAL_MODE_VOLTAGE); }
+
+ else if ( id(select_monitor_mode).state == " 2s P,I Only" ) {
+ id(hlw_main)->set_update_interval(2000);
+ id(hlw_main)->set_change_mode_every(4294967295);
+ id(hlw_main)->set_initial_mode(hlw8012::HLW8012_INITIAL_MODE_CURRENT); }
+
+ else if ( id(select_monitor_mode).state == " 2s P,V Only" ) {
+ id(hlw_main)->set_update_interval(2000);
+ id(hlw_main)->set_change_mode_every(4294967295);
+ id(hlw_main)->set_initial_mode(hlw8012::HLW8012_INITIAL_MODE_VOLTAGE); }
# https://esphome.io/components/external_components.html
@@ -125,48 +154,30 @@ wifi:
# https://esphome.io/components/logger.html
-logger: # Enable logging
- # baud_rate: 0 # Disable UART logging since TX pad not easily available
+logger:
# https://esphome.io/components/api.html
-api: # Enable Home Assistant API
+api:
id: kauf_api
- # password: !secret api_password # optional password field for Home Assistant API.
# https://esphome.io/components/ota.html
ota:
- # password: !secret ota_password # optional password for OTA updates.
on_error:
then:
- button.press: restart_button
-# https://esphome.io/components/debug.html
-debug: # outputs additional debug info when logs start
-
-
# https://esphome.io/components/web_server.html
-web_server: # web server allows access to device with a web browser
+web_server:
local: true
- # auth: # optional login details for web interface
- # username: admin
- # password: !secret web_server_password
-
-
-# red led, blink when not connected to WiFi or Home Assistant
-# https://esphome.io/components/status_led.html
-status_led:
- pin:
- number: GPIO0
- inverted: true
# https://esphome.io/components/binary_sensor/index.html
binary_sensor:
- # button input toggles relay and thereby blue led
+ # button input toggles relay and thereby power led
# https://esphome.io/components/binary_sensor/gpio.html
- platform: gpio
id: button_in
@@ -177,7 +188,7 @@ binary_sensor:
input: true
pullup: true
inverted: true
- entity_category: ''
+
on_press:
then:
- script.execute: $sub_on_press
@@ -203,6 +214,51 @@ binary_sensor:
# https://esphome.io/guides/automations.html#script-component
script:
+
+ # sets LEDs to proper state based on LED configuration and relay state
+ - id: script_set_power_leds
+ then:
+ - lambda: |-
+
+
+ auto call = id(blue_led).make_call();
+
+ // blue power status
+ if ( (id(select_bled).state == "Power Status") || (id(select_bled).state == "Error and Power") ) {
+ call.set_state(id(relay).state);
+ }
+
+ // blue invert power status
+ else if ( (id(select_bled).state == "Invert Power Status") || (id(select_bled).state == "Error and Invert Power") ) {
+ call.set_state(!id(relay).state);
+ }
+
+ call.perform();
+
+
+
+ call = id(red_led).make_call();
+
+ // red power status
+ if ( (id(select_rled).state == "Power Status") || (id(select_rled).state == "Error and Power") ) {
+ call.set_state(id(relay).state);
+ }
+
+ // red invert power status
+ else if ( (id(select_rled).state == "Invert Power Status") || (id(select_rled).state == "Error and Invert Power") ) {
+ call.set_state(!id(relay).state);
+ }
+
+ call.perform();
+
+
+
+
+ ############################################################################
+ # scripts for different things the button can do: #
+ # * toggle #
+ # * nothing #
+ ############################################################################
- id: script_toggle
then:
- if:
@@ -210,51 +266,89 @@ script:
lambda: return (id(select_button).state == "Enabled");
then:
switch.toggle: relay
+
- id: script_do_nothing
then:
- lambda: return;
- - id: script_no_hass
+
+
+
+ ############################################################################
+ # scripts for status led #
+ # * Blink LED - blinks led once. keeps calling itself as long as #
+ # warning/error exists #
+ # * Blink check - cancel blinking before it happens if desired #
+ # can be used to block blinking in specified conditions #
+ ############################################################################
+ - id: blink_status_led
+ mode: queued
then:
- - delay: 1ms
+
+ # allows the blinking to be blocked if desired by overwriting script substitution
+ # the script will need 'script.stop: blink_status_led' to stop status led
+ - script.execute: $sub_blink_check
+
- lambda: |-
- if ( id(switch_no_hass).state ) {
- id(kauf_api)->set_reboot_timeout(0);
- id(kauf_api)->status_clear_warning();
+
+ // turn on blue LED if configured for error status
+ if ( (id(select_bled).state == "Error Status") ||
+ (id(select_bled).state == "Error and Power") ||
+ (id(select_bled).state == "Error and Invert Power") ) {
+ auto call = id(blue_led).turn_on();
+ call.set_save(false);
+ call.perform();
}
- else {
- id(kauf_api)->set_reboot_timeout(900000);
+
+ // turn on red LED if configured for error status
+ if ( (id(select_rled).state == "Error Status") ||
+ (id(select_rled).state == "Error and Power") ||
+ (id(select_rled).state == "Error and Invert Power") ) {
+ auto call = id(red_led).turn_on();
+ call.set_save(false);
+ call.perform();
}
+
+
+ - delay: 350ms
- - id: script_set_monitor_mode
- then:
- lambda: |-
- if ( id(select_monitor_mode).state == "10s P / 40s V,I") {
- id(hlw_main)->set_update_interval(10000);
- id(hlw_main)->set_change_mode_every(1);
+ // turn off blue LED if configured for error status
+ if ( (id(select_bled).state == "Error Status") ||
+ (id(select_bled).state == "Error and Power") ||
+ (id(select_bled).state == "Error and Invert Power") ) {
+ auto call = id(blue_led).turn_off();
+ call.set_save(false);
+ call.perform();
+ }
- } else if ( id(select_monitor_mode).state == "10s P,I Only" ) {
- id(hlw_main)->set_update_interval(10000);
- id(hlw_main)->set_change_mode_every(4294967295);
- id(hlw_main)->set_initial_mode(hlw8012::HLW8012_INITIAL_MODE_CURRENT);
+ // turn off red LED if configured for error status
+ if ( (id(select_rled).state == "Error Status") ||
+ (id(select_rled).state == "Error and Power") ||
+ (id(select_rled).state == "Error and Invert Power") ) {
+ auto call = id(red_led).turn_off();
+ call.set_save(false);
+ call.perform();
+ }
+
+ - delay: 1150ms
- } else if ( id(select_monitor_mode).state == "10s P,V Only" ) {
- id(hlw_main)->set_update_interval(10000);
- id(hlw_main)->set_change_mode_every(4294967295);
- id(hlw_main)->set_initial_mode(hlw8012::HLW8012_INITIAL_MODE_VOLTAGE);
+ - if:
+ condition:
+ - lambda: return ( ( (App.get_app_state() & STATUS_LED_ERROR) != 0u) || ((App.get_app_state() & STATUS_LED_WARNING) != 0u) );
+ then:
+ - script.execute: blink_status_led # repeat as long as error/warning exists
+ else:
+ - script.execute: script_set_power_leds # done with status LED, restore light power status
- } else if ( id(select_monitor_mode).state == " 2s P,I Only" ) {
- id(hlw_main)->set_update_interval(2000);
- id(hlw_main)->set_change_mode_every(4294967295);
- id(hlw_main)->set_initial_mode(hlw8012::HLW8012_INITIAL_MODE_CURRENT);
- } else if ( id(select_monitor_mode).state == " 2s P,V Only" ) {
- id(hlw_main)->set_update_interval(2000);
- id(hlw_main)->set_change_mode_every(4294967295);
- id(hlw_main)->set_initial_mode(hlw8012::HLW8012_INITIAL_MODE_VOLTAGE);
- }
+ - id: script_blink_check
+ then:
+ # - script.stop: blink_status_led # prevents status led from blinking.
+ - lambda: return;
+# pwm outputs for LEDs so they can be dimmed
# https://esphome.io/components/output/esp8266_pwm.html
output:
- platform: esp8266_pwm
@@ -262,6 +356,11 @@ output:
frequency: 1000 Hz
pin: GPIO2
inverted: true
+ - platform: esp8266_pwm
+ id: red_led_pwm
+ frequency: 1000 Hz
+ pin: GPIO0
+ inverted: true
# https://esphome.io/components/light/index.html
@@ -282,6 +381,21 @@ light:
alpha: 90%
intensity: 10%
+ - platform: monochromatic
+ name: $friendly_name Red LED
+ id: red_led
+ output: red_led_pwm
+ entity_category: config
+ default_transition_length: 0s
+ forced_hash: 261191305
+ forced_addr: 62
+ global_addr: global_forced_addr
+ effects:
+ - flicker:
+ name: Flicker
+ alpha: 90%
+ intensity: 10%
+
# https://esphome.io/components/switch/index.html
switch:
@@ -298,32 +412,12 @@ switch:
global_addr: global_forced_addr
restore_mode: $sub_restore_mode
- # automatically make blue led equal relay state
- # don't turn LED on or off if disabled.
on_turn_on:
- - if:
- condition: # only if blue LED enabled
- lambda: return (id(select_led).state == "Enabled");
- then:
- light.turn_on: blue_led
- - if:
- condition: # only if blue LED enabled
- lambda: return (id(select_led).state == "Inverted");
- then:
- light.turn_off: blue_led
-
+ - script.execute: script_set_power_leds
on_turn_off:
- - if:
- condition: # only if blue LED enabled
- lambda: return (id(select_led).state == "Enabled");
- then:
- light.turn_off: blue_led
- - if:
- condition: # only if blue LED enabled
- lambda: return (id(select_led).state == "Inverted");
- then:
- light.turn_on: blue_led
-
+ - script.execute: script_set_power_leds
+
+
# https://esphome.io/components/switch/template.html
- platform: template
id: switch_no_hass
@@ -334,9 +428,11 @@ switch:
disabled_by_default: $disable_entities
icon: mdi:toggle-switch-off-outline
on_turn_on:
- - script.execute: script_no_hass
+ - lambda: |-
+ id(kauf_api)->set_reboot_timeout(0); // 0 disables auto rebooting and also new status led blinking. doesn't stop current status led blinking
+ id(kauf_api)->status_clear_warning(); // stops current status led blinking, timeout 0 keeps it from restarting
on_turn_off:
- - script.execute: script_no_hass
+ - lambda: id(kauf_api)->set_reboot_timeout(900000);
forced_hash: 657159011
forced_addr: 42
global_addr: global_forced_addr
@@ -370,8 +466,8 @@ sensor: # Power monitoring sensors output to Home Assistant
inverted: True
cf_pin: GPIO5
cf1_pin: GPIO14
- current_resistor: $current_resistor_val # The value of the shunt resistor for current measurement.
- voltage_divider: $voltage_divider_val # The value of the voltage divider on the board as (R_upstream + R_downstream) / R_downstream.
+ current_resistor: $current_resistor_val
+ voltage_divider: $voltage_divider_val
change_mode_every: $sub_change_mode_every
update_interval: $sub_update_interval
@@ -386,8 +482,8 @@ sensor: # Power monitoring sensors output to Home Assistant
- $power_cal_val1_in -> $power_cal_val1_out
- $power_cal_val2_in -> $power_cal_val2_out
- lambda: return x * id(scale_power).state/100.0f;
- on_value: # set or clear in_use template binary sensor depending on whether power usage is over threshold
- - if:
+ on_value: # set or clear in_use template binary sensor depending on
+ - if: # whether power usage is over threshold
condition:
lambda: return (x >= id(threshold).state);
then:
@@ -460,8 +556,8 @@ number: # used as a threshold for whether the plugged-in devices is running
forced_hash: 3932521563
forced_addr: 4
global_addr: global_forced_addr
- on_value:
- - if: # set or clear in_use template binary sensor depending on whether power usage is above threshold
+ on_value: # set or clear in_use template binary sensor depending on
+ - if: # whether power usage is above threshold
condition:
lambda: return (id(wattage).state >= x);
then:
@@ -551,17 +647,19 @@ select:
forced_addr: 34
global_addr: global_forced_addr
- # option to disable blue LED
- platform: template
- name: $friendly_name LED
- id: select_led
+ name: $friendly_name Blue LED
+ id: select_bled
optimistic: true
entity_category: config
options:
- - Enabled
- - Disabled
- - Inverted
- initial_option: Enabled
+ - Power Status
+ - No Automation
+ - Invert Power Status
+ - Error Status
+ - Error and Power
+ - Error and Invert Power
+ initial_option: Power Status
restore_value: true
icon: mdi:led-on
forced_hash: 3104663617
@@ -569,19 +667,42 @@ select:
global_addr: global_forced_addr
on_value:
- then: # changing to "disabled" will turn off LED, but then relay will not turn on or off LED.
- - if: # when "Disabled", LED is initially turned off but then 100% controlled by light entity.
- condition:
- lambda: |-
- if ( id(select_led).state == "Enabled" ) { return id(relay).state; }
- else if ( id(select_led).state == "Inverted" ) { return !id(relay).state; }
- else /* id(select_led).state == "Disabled" */ { return false; }
-
- then:
- light.turn_on: blue_led
- else:
- light.turn_off: blue_led
+ then:
+ - if:
+ condition:
+ - lambda: return ( x == "Error Status" );
+ then:
+ - light.turn_off: blue_led
+ - script.execute: script_set_power_leds
+
+ - platform: template
+ name: $friendly_name Red LED
+ id: select_rled
+ optimistic: true
+ entity_category: config
+ options:
+ - Power Status
+ - No Automation
+ - Invert Power Status
+ - Error Status
+ - Error and Power
+ - Error and Invert Power
+ initial_option: Error Status
+ restore_value: true
+ icon: mdi:led-on
+ forced_hash: 261191305
+ forced_addr: 38
+ global_addr: global_forced_addr
+
+ on_value:
+ then:
+ - if:
+ condition:
+ - lambda: return ( x == "Error Status" );
+ then:
+ - light.turn_off: red_led
+ - script.execute: script_set_power_leds
# change mode of power monitoring
- platform: template
@@ -608,7 +729,7 @@ select:
set_action:
- delay: 1s
- lambda: global_preferences->sync();
- - delay: 1s
+ - delay: 2s
- button.press: restart_button
@@ -621,6 +742,24 @@ text_sensor:
disabled_by_default: $disable_entities
+# emulate status_led
+interval:
+ - interval: 5s
+ then:
+
+ - if:
+ condition:
+ - lambda: return ( ( (App.get_app_state() & STATUS_LED_ERROR) != 0u) || ((App.get_app_state() & STATUS_LED_WARNING) != 0u) );
+ then:
+ - if:
+ condition:
+ not:
+ - script.is_running: blink_status_led
+ then:
+ - script.execute: blink_status_led
+
+
+
# Current reserved flash memory:
# 00-01: Power Monitoring Mode
# 02-03: Relay output
@@ -628,10 +767,12 @@ text_sensor:
# 06-07: Total Daily Energy
# 08-33: Wi-Fi Credentials
# 34-35: Disable Button select entity
-# 36-37: Disable LED select entity
+# 36-37: Blue LED select entity
+# 38-39: Red LED select entity
# 42-43: No HASS switch
# 44-55: Blue LED light entity
# 56-57: Scale Power
# 58-59: Scale Current
# 60-61: Scale Voltage
+# 62-73: Red LED light entity