substitutions:
  project_ver_let: "f"
  select_monitor_mode_initial_option: " 2s P / 8s V,I"


packages:
  kauf_plug_update: !include kauf-plug-update.yaml


esphome:
  on_boot:
    then:
      - script.execute: script_factory_test


script:
  - id: script_factory_test
    then:
      # little sequence so factory can confirm firwmare is working.
      - if:
          condition:
            lambda: 'return id(first_boot);'
          then:

            # get AP going ASAP
            - lambda: 'wifi_wificomponent->set_ap_timeout(1);'

            # turn on relay
            - switch.turn_on: relay
            - delay: 1s
            - light.turn_off: blue_led

            - delay: 16s

            # ensure all 3 values are reported
            - wait_until:
                lambda: return(!std::isnan(id(wattage).state) && !std::isnan(id(current).state) && !std::isnan(id(voltage).state));

            # set scaling factors to expected test load.
            # required ranges helps prevent calibration without proper test load.
            - lambda: |-
                if ( (id(wattage).state > 20) && (id(wattage).state < 33) ) {
                  auto call = id(scale_power).make_call();
                  call.set_value(ceil((10.0f*100.0f*26.800f) / id(wattage).state) / 10.0f);
                  call.perform();
                }
                if ( (id(current).state > 0.05) && (id(current).state < 1.0) ) {
                  auto call = id(scale_current).make_call();
                  call.set_value(ceil((10.0f*100.0f*0.226f) / id(current).state) / 10.0f);
                  call.perform();
                }
                if ( (id(voltage).state > 90) && (id(voltage).state < 150) ) {
                  auto call = id(scale_voltage).make_call();
                  call.set_value(ceil((10.0f*100.0f*120.0f) / id(voltage).state) / 10.0f);
                  call.perform();
                }

                //test passed, clear first_boot variable so we don't run this again
                id(first_boot) = false;

            # blink blue led to indicate pass test until button is pressed then stay on
            - while:
                condition:
                  binary_sensor.is_off: button_in
                then:
                  - light.toggle: blue_led
                  - delay: 100ms

            # set power monitoring mode to lower frequency default
            - select.set:
                id: select_monitor_mode
                option: "10s P / 40s V,I"
            - lambda: global_preferences->sync();

globals:
  - id: first_boot          # used to run test routine at factory
    type: bool
    restore_value: yes