diff options
Diffstat (limited to 'Documentation/HardwareIssues.md')
-rw-r--r-- | Documentation/HardwareIssues.md | 2 |
1 files changed, 1 insertions, 1 deletions
diff --git a/Documentation/HardwareIssues.md b/Documentation/HardwareIssues.md index 423f9a07..16fd7c95 100644 --- a/Documentation/HardwareIssues.md +++ b/Documentation/HardwareIssues.md @@ -28,7 +28,7 @@ The best way to see if this is the case is to measure the resistance across the you are expecting to see measurements in the range of 4-10 ohms. Anything higher than 10 ohms is _generally_ an issue. ## Iron will not heat up and displays a high temperature -Check the Rtip and CHan numbers ([see debug menu](/Documentation/DebugMenu.md)). Extremly high CHan is suspect to a problem with the cold junction compensation temperature sensor. +Check the Rtip and CHan numbers ([see debug menu](https://ralim.github.io/IronOS/DebugMenu/)). Extremly high CHan is suspect to a problem with the cold junction compensation temperature sensor. For Pinecil V1, inspect near U10 which is the TMP36 sensor ([see issue here](https://github.com/Ralim/IronOS/issues/1234)). You may be able to reflow/resolder the TMP36 chip at U10 to correct a weak solder joint. |