//go:build nucleol552ze package machine import ( "device/stm32" "runtime/interrupt" ) const ( LED_GREEN = PC7 LED_BLUE = PB7 LED_RED = PA9 LED_BUILTIN = LED_GREEN LED = LED_BUILTIN ) const ( BUTTON = BUTTON_USER BUTTON_USER = PC13 ) // UART pins const ( // PG7 and PG8 are connected to the ST-Link Virtual Com Port (VCP) UART_TX_PIN = PG7 UART_RX_PIN = PG8 UART_ALT_FN = 8 // GPIO_AF8_LPUART1 ) var ( // LPUART1 is the hardware serial port connected to the onboard ST-LINK // debugger to be exposed as virtual COM port over USB on Nucleo boards. UART1 = &_UART1 _UART1 = UART{ Buffer: NewRingBuffer(), Bus: stm32.LPUART1, TxAltFuncSelector: UART_ALT_FN, RxAltFuncSelector: UART_ALT_FN, } DefaultUART = UART1 ) const ( I2C0_SCL_PIN = PB8 I2C0_SDA_PIN = PB9 ) var ( // I2C1 is documented, alias to I2C0 as well I2C1 = &I2C{ Bus: stm32.I2C1, AltFuncSelector: 4, } I2C0 = I2C1 ) func init() { UART1.Interrupt = interrupt.New(stm32.IRQ_LPUART1, _UART1.handleInterrupt) }