diff options
author | Kaufman Home Automation <[email protected]> | 2022-05-17 22:47:22 -0700 |
---|---|---|
committer | GitHub <[email protected]> | 2022-05-17 22:47:22 -0700 |
commit | 256d125f215138b94415bd50a89dc87164e7e55f (patch) | |
tree | 372da96a919092d786068bd763685a7330d75eb8 | |
parent | d145a0c74fb40aa6577911875da114c885abd555 (diff) | |
download | PLF10-256d125f215138b94415bd50a89dc87164e7e55f.tar.gz PLF10-256d125f215138b94415bd50a89dc87164e7e55f.zip |
v1.96
-rw-r--r-- | kauf-plug-lite.yaml | 345 |
1 files changed, 161 insertions, 184 deletions
diff --git a/kauf-plug-lite.yaml b/kauf-plug-lite.yaml index 037faa9..b66762e 100644 --- a/kauf-plug-lite.yaml +++ b/kauf-plug-lite.yaml @@ -6,24 +6,23 @@ substitutions: # in your local yaml file by redefining them. # # packages: - # kauf.plf10: github://bkaufx/PLF10/kauf-plug-lite.yaml + # kauf.plf10: github://KaufHA/PLF10/kauf-plug.yaml # name: kauf-plug # **** CHANGE DEVICE NAME TO SOMETHING UNIQUE PER DEVICE. RENAME YAML FILE TO SAME NAME. **** # **** USE DASHES (-) INSTEAD OF SPACES OR UNDERSCORE (_). USE ONLY LOWER CASE LETTERS. **** - friendly_name: Kauf Plug # **** CHANGE FRIENDLY NAME TO SOMETHING UNIQUE PER DEVICE **** + friendly_name: Kauf Plug # **** CHANGE FRIENDLY NAME TO SOMETHING UNIQUE PER DEVICE **** # https://esphome.io/components/esphome.html#esphome-creators-project project_name: Kauf.PLF10 - project_ver_num: "1.95" - project_ver_let: l + project_ver_num: "1.96" + project_ver_let: y # https://esphome.io/components/switch/gpio.html?highlight=restore_mode sub_restore_mode: RESTORE_DEFAULT_OFF # overwrite to change boot up behavior of relay disable_entities: "true" # set to "false" to have all entities show up in Home Assistant automatically - # substitutions for button actions. on_press and on_release implement a timer scheme with configurable delay. # on_hold_5s re-enables the AP and captive portal for the precompiled update binary. # any length of hold can be implemented with just on_press and on_release using the following directions. This @@ -33,17 +32,16 @@ substitutions: # * place actions in the on_press script after the delay to perform them while still holding the button # * place actions in the on_release script, with the condition that the on_press script is not running, to # perform them on release of the button. - sub_on_press: script_start_timer # executes right when button is initially pressed - sub_on_release: script_stop_timer # executes right when button is released + sub_on_press: script_do_nothing # executes right when button is initially pressed + sub_on_release: script_do_nothing # executes right when button is released sub_on_hold_5s: script_do_nothing # executes right when button has been held for 5s, while button is still being held - sub_on_release_quick: script_do_nothing # executes when button is released after being held under 750ms - sub_on_release_short: script_do_nothing # executes when button is released after being held between 750ms and 5s - sub_on_release_long: script_do_nothing # executes when button is released after being held between 5s and 60s # an extra script that, if running, will stop the relay from toggling on button release. # used to not toggle when WiFi AP is re-enabled on update bin file. - sub_toggle_check: script_start_timer + sub_toggle_check: script_do_nothing + # made this a substitution so that the update bin file and yaml compiled versions can have different defaults + default_button_config: "Toggle on Press" # substitutions for power monitoring calibration. Allows end users to change calibration in their yaml and still # incorporate this file as a package to get all the updates we release. @@ -74,6 +72,15 @@ substitutions: esp8266: board: esp01_1m restore_from_flash: true + early_pin_init: false + + +# https://esphome.io/guides/automations.html#global-variables +globals: + - id: global_press_time + type: int + restore_value: no + initial_value: '0' # https://esphome.io/components/esphome.html#adjusting-flash-writes @@ -92,36 +99,9 @@ esphome: on_boot: priority: 700 then: - - # priority 700 ensures power monitoring mode variables are changed - # in this script before HLW component is setup - # hlw_main will already have the YAML configured values by default, so - # no need to handle that here. - - lambda: |- - - if ( id(select_monitor_mode).state == "10s P / 40s V,I") { - id(hlw_main)->set_update_interval(10000); - id(hlw_main)->set_change_mode_every(1); } - - else if ( id(select_monitor_mode).state == "10s P,I Only" ) { - id(hlw_main)->set_update_interval(10000); - id(hlw_main)->set_change_mode_every(4294967295); - id(hlw_main)->set_initial_mode(hlw8012::HLW8012_INITIAL_MODE_CURRENT); } - - else if ( id(select_monitor_mode).state == "10s P,V Only" ) { - id(hlw_main)->set_update_interval(10000); - id(hlw_main)->set_change_mode_every(4294967295); - id(hlw_main)->set_initial_mode(hlw8012::HLW8012_INITIAL_MODE_VOLTAGE); } - - else if ( id(select_monitor_mode).state == " 2s P,I Only" ) { - id(hlw_main)->set_update_interval(2000); - id(hlw_main)->set_change_mode_every(4294967295); - id(hlw_main)->set_initial_mode(hlw8012::HLW8012_INITIAL_MODE_CURRENT); } - - else if ( id(select_monitor_mode).state == " 2s P,V Only" ) { - id(hlw_main)->set_update_interval(2000); - id(hlw_main)->set_change_mode_every(4294967295); - id(hlw_main)->set_initial_mode(hlw8012::HLW8012_INITIAL_MODE_VOLTAGE); } + # implementing on_boot function as a script so that any other on_boot automations in other files + # will execute in parallel and not be blocked by this one. + - script.execute: on_boot_main # https://esphome.io/components/wifi.html @@ -173,26 +153,30 @@ binary_sensor: input: true pullup: true inverted: true - on_press: then: + - lambda: |- + // store time of press and clear duration sensor + id(global_press_time) = millis(); + id(sensor_press_duration).publish_state(0); + + // toggle if configured for toggle on press + if (id(select_button).state == "Toggle on Press") { + id(relay).toggle(); } - script.execute: $sub_on_press + - script.execute: script_5s_timer on_release: then: + - lambda: |- + // set duration sensor + id(sensor_press_duration).publish_state(millis() - id(global_press_time) + id(number_debounce).state); + + // toggle if configured on release and toggle check script is not running. + if ( (id(select_button).state == "Toggle on Release") && !id($sub_toggle_check).is_running() ) { + id(relay).toggle(); + } - script.execute: $sub_on_release - on_click: - - min_length: 20ms - max_length: 750ms - then: - - script.execute: $sub_on_release_quick - - min_length: 750ms - max_length: 5s - then: - - script.execute: $sub_on_release_short - - min_length: 5s - max_length: 60s - then: - - script.execute: $sub_on_release_long + - script.stop: script_5s_timer # indicates whether plugged-in device is running based on configurable threshold. # https://esphome.io/components/binary_sensor/template.html @@ -211,31 +195,25 @@ script: auto call = id(blue_led).make_call(); - // blue power status + // if blue led follows power status if ( (id(select_bled).state == "Power Status") || (id(select_bled).state == "Error and Power") ) { call.set_state(id(relay).state); } - // blue invert power status + // if blue led follows inverse of power status else if ( (id(select_bled).state == "Invert Power Status") || (id(select_bled).state == "Error and Invert Power") ) { call.set_state(!id(relay).state); } + // if blue led is set to not change on power status (error only or disabled), performing an empty call does nothing. call.perform(); - + // same as blue but for red led call = id(red_led).make_call(); - - // red power status if ( (id(select_rled).state == "Power Status") || (id(select_rled).state == "Error and Power") ) { - call.set_state(id(relay).state); - } - - // red invert power status + call.set_state(id(relay).state); } else if ( (id(select_rled).state == "Invert Power Status") || (id(select_rled).state == "Error and Invert Power") ) { - call.set_state(!id(relay).state); - } - + call.set_state(!id(relay).state); } call.perform(); - id: blink_status_led @@ -294,84 +272,80 @@ script: else: - script.execute: script_set_power_leds # done with status LED, restore light power status - - ############################################################################ - # scripts for different things the button can do: # - # * start timer (on press) # - # * stop timer (on release) # - # * nothing # - ############################################################################ - - id: script_start_timer - then: - - # store press time in ms - - lambda: id(global_press_time) = millis(); - - - script.execute: script_5s_timer - - # variable delay before toggling plug - - delay: !lambda |- - if ( id(select_button).state == "Toggle if Pressed For 20ms" ) - return 20; - else if ( id(select_button).state == "Toggle if Released After 20ms" ) - return 20; - else if ( id(select_button).state == "Toggle if Pressed For 100ms" ) - return 100; - else if ( id(select_button).state == "Toggle if Released After 100ms" ) - return 100; - else if ( id(select_button).state == "Toggle if Pressed For 250ms" ) - return 250; - else if ( id(select_button).state == "Toggle if Released After 250ms" ) - return 250; - else - return 1000; - - # toggle immediately after delay if a "pressed" option is selected + - id: script_new_debounce + mode: restart # only reboot plug once number is static for 10s. changing value again restarts timer. + then: # only do it if wifi is connected, keeps initial loading of value on boot from causing restart. - if: condition: - lambda: |- - std::size_t found = id(select_button).state.find("Press"); - return (found != std::string::npos); - then: - - switch.toggle: relay - - - id: script_stop_timer - then: - - # set duration sensor - - lambda: id(sensor_press_duration).publish_state(millis() - id(global_press_time)); - - - if: - condition: # potentially toggle if a "released" option is selected - lambda: |- - std::size_t found = id(select_button).state.find("Release"); - return (found != std::string::npos); + - wifi.connected then: - - - if: - condition: - or: # do nothing if timer is still running or toggle check script is running. - - script.is_running: script_start_timer - - script.is_running: $sub_toggle_check - then: - - script.execute: script_do_nothing - else: # otherwise toggle relay - - switch.toggle: relay - - # in all cases, stop timers on button release. - - script.stop: script_5s_timer - - script.stop: script_start_timer - + - lambda: ESP_LOGD("kauf-plug.yaml","New debounce value detected, rebooting in 10 seconds to effect change."); + - delay: 10s + - button.press: restart_button - id: script_5s_timer then: - - delay: 5s + - delay: !lambda return (5000-id(number_debounce).state); - script.execute: $sub_on_hold_5s - id: script_do_nothing then: - lambda: return; + - id: on_boot_main + then: + + # this on_boot script has to execute after select and number entities are set up, so + # priority < 800. Adding a check here to make sure all needed entities are set up just + # in case another yaml file makes on_boot priority higher than 800 the following code + # will still work right. If on_boot priority becomes <= 600, the code for setting up + # power monitoring mode won't work because HLW will already be set up before values are + # changed in this script. + - wait_until: + lambda: return (id(select_monitor_mode).has_state() ); + + - lambda: |- + + ////////////////////////////////////////////////////////////////////// + // implement power monitoring mode per select entity + + if ( id(select_monitor_mode).state == "10s P / 40s V,I") { + id(hlw_main).set_update_interval(10000); + id(hlw_main).set_change_mode_every(1); } + + else if ( id(select_monitor_mode).state == "10s P,I Only" ) { + id(hlw_main).set_update_interval(10000); + id(hlw_main).set_change_mode_every(4294967295); + id(hlw_main).set_initial_mode(hlw8012::HLW8012_INITIAL_MODE_CURRENT); } + + else if ( id(select_monitor_mode).state == "10s P,V Only" ) { + id(hlw_main).set_update_interval(10000); + id(hlw_main).set_change_mode_every(4294967295); + id(hlw_main).set_initial_mode(hlw8012::HLW8012_INITIAL_MODE_VOLTAGE); } + + else if ( id(select_monitor_mode).state == " 2s P,I Only" ) { + id(hlw_main).set_update_interval(2000); + id(hlw_main).set_change_mode_every(4294967295); + id(hlw_main).set_initial_mode(hlw8012::HLW8012_INITIAL_MODE_CURRENT); } + + else if ( id(select_monitor_mode).state == " 2s P,V Only" ) { + id(hlw_main).set_update_interval(2000); + id(hlw_main).set_change_mode_every(4294967295); + id(hlw_main).set_initial_mode(hlw8012::HLW8012_INITIAL_MODE_VOLTAGE); } + + ////////////////////////////////////////////////////////////////////// + // add a delayed_on filter to the button binary_sensor with time argument from number_debounce. + // this is placed after settings recovery so that it will take into account recovered setting + // on first boot. In any case, needs to be after priority 800 so that number_debounce is set up. + + binary_sensor::DelayedOnFilter *button_delayedonfilter; + button_delayedonfilter = new binary_sensor::DelayedOnFilter(id(number_debounce).state); + button_delayedonfilter->set_component_source("binary_sensor"); + App.register_component(button_delayedonfilter); + id(button_in).add_filters({button_delayedonfilter}); + + + # pwm outputs for LEDs so they can be dimmed # https://esphome.io/components/output/esp8266_pwm.html @@ -388,6 +362,7 @@ output: inverted: true +# light entities for blue and red LEDs # https://esphome.io/components/light/index.html # https://esphome.io/components/light/monochromatic.html light: @@ -427,13 +402,11 @@ switch: pin: GPIO4 entity_category: '' restore_mode: $sub_restore_mode - on_turn_on: - script.execute: script_set_power_leds on_turn_off: - script.execute: script_set_power_leds - # https://esphome.io/components/switch/template.html - platform: template id: switch_no_hass @@ -445,10 +418,10 @@ switch: icon: mdi:toggle-switch-off-outline on_turn_on: - lambda: |- - id(kauf_api)->set_reboot_timeout(0); // 0 disables auto rebooting and also new status led blinking. doesn't stop current status led blinking - id(kauf_api)->status_clear_warning(); // stops current status led blinking, timeout 0 keeps it from restarting + id(kauf_api).set_reboot_timeout(0); // 0 disables auto rebooting and also new status led blinking. doesn't stop current status led blinking + id(kauf_api).status_clear_warning(); // stops current status led blinking, timeout 0 keeps it from restarting on_turn_off: - - lambda: id(kauf_api)->set_reboot_timeout(900000); + - lambda: id(kauf_api).set_reboot_timeout(900000); # https://esphome.io/components/button/index.html @@ -495,18 +468,8 @@ sensor: # Power monitoring sensors output to Home Assistant - $power_cal_val1_in -> $power_cal_val1_out - $power_cal_val2_in -> $power_cal_val2_out - lambda: return x * id(scale_power).state/100.0f; - on_value: # set or clear in_use template binary sensor depending on - - if: # whether power usage is over threshold - condition: - lambda: return (x >= id(threshold).state); - then: - - binary_sensor.template.publish: - id: in_use - state: ON - else: - - binary_sensor.template.publish: - id: in_use - state: OFF + on_value: # set or clear in_use template binary sensor depending on whether power usage is over threshold + - lambda: id(in_use).publish_state(x >= id(threshold).state); current: name: ${friendly_name} Current @@ -528,7 +491,6 @@ sensor: # Power monitoring sensors output to Home Assistant - $voltage_cal_val2_in -> $voltage_cal_val2_out - lambda: return x * id(scale_voltage).state/100.0f; - # Reports the total Power so-far each day, resets at midnight # https://esphome.io/components/sensor/total_daily_energy.html - platform: total_daily_energy @@ -546,6 +508,7 @@ sensor: # Power monitoring sensors output to Home Assistant entity_category: diagnostic disabled_by_default: $disable_entities + # https://esphome.io/components/sensor/template.html - platform: template name: $friendly_name Button Press Duration id: sensor_press_duration @@ -571,18 +534,8 @@ number: # used as a threshold for whether the plugged-in devices is running unit_of_measurement: Watt(s) mode: box disabled_by_default: $disable_entities - on_value: # set or clear in_use template binary sensor depending on - - if: # whether power usage is above threshold - condition: - lambda: return (id(wattage).state >= x); - then: - - binary_sensor.template.publish: - id: in_use - state: ON - else: - - binary_sensor.template.publish: - id: in_use - state: OFF + on_value: # set or clear in_use template binary sensor depending on whether power usage is above threshold + - lambda: id(in_use).publish_state(id(wattage).state >= x); - platform: template name: ${friendly_name} Scale Power @@ -597,8 +550,8 @@ number: # used as a threshold for whether the plugged-in devices is running unit_of_measurement: "%" mode: box disabled_by_default: $disable_entities - on_value: - - lambda: id(wattage)->publish_state(id(wattage)->get_raw_state()); + on_value: # republish value. Sensor automation applies new scaling factor. + - lambda: id(wattage).publish_state(id(wattage).get_raw_state()); - platform: template name: ${friendly_name} Scale Current @@ -613,8 +566,8 @@ number: # used as a threshold for whether the plugged-in devices is running unit_of_measurement: "%" mode: box disabled_by_default: $disable_entities - on_value: - - lambda: id(current)->publish_state(id(current)->get_raw_state()); + on_value: # republish value. Sensor automation applies new scaling factor. + - lambda: id(current).publish_state(id(current).get_raw_state()); - platform: template name: ${friendly_name} Scale Voltage @@ -629,30 +582,38 @@ number: # used as a threshold for whether the plugged-in devices is running unit_of_measurement: "%" mode: box disabled_by_default: $disable_entities - on_value: - - lambda: id(voltage)->publish_state(id(voltage)->get_raw_state()); - + on_value: # republish value. Sensor automation applies new scaling factor. + - lambda: id(voltage).publish_state(id(voltage).get_raw_state()); + + - platform: template + name: ${friendly_name} Debounce Time + min_value: 50 + max_value: 2000 + step: 1 + initial_value: 75 + id: number_debounce + entity_category: config + optimistic: true + restore_value: true + unit_of_measurement: "ms" + mode: box + disabled_by_default: $disable_entities + on_value: # currently, have to reboot plug to apply new delayed_on time + - script.execute: script_new_debounce # https://esphome.io/components/select/index.html # https://esphome.io/components/select/template.html select: - # option to disable button - platform: template name: $friendly_name Button Config id: select_button optimistic: true options: - - Toggle if Pressed For 20ms - - Disable Button - - Toggle if Pressed For 100ms - - Toggle if Pressed For 250ms - - Toggle if Pressed For 1s - - Toggle if Released After 20ms - - Toggle if Released After 100ms - - Toggle if Released After 250ms - - Toggle if Released After 1s - initial_option: Toggle if Pressed For 100ms + - Toggle on Press + - Toggle on Release + - Don't Toggle + initial_option: $default_button_config restore_value: true icon: mdi:circle-double entity_category: config @@ -703,7 +664,6 @@ select: - lambda: return ( x == "Error Status" ); then: - light.turn_off: red_led - - script.execute: script_set_power_leds # change mode of power monitoring @@ -723,7 +683,6 @@ select: icon: mdi:wrench-clock entity_category: config disabled_by_default: $disable_entities - set_action: - delay: 1s - lambda: global_preferences->sync(); @@ -741,10 +700,10 @@ text_sensor: # emulate status_led +# https://esphome.io/guides/automations.html#interval-component interval: - interval: 5s then: - - if: condition: - lambda: return ( ( (App.get_app_state() & STATUS_LED_ERROR) != 0u) || ((App.get_app_state() & STATUS_LED_WARNING) != 0u) ); @@ -755,3 +714,21 @@ interval: - script.is_running: blink_status_led then: - script.execute: blink_status_led + + +# Current reserved flash memory: +# 00-01: Power Monitoring Mode +# 02-03: Relay output +# 04-05: Use Threshold +# 06-07: Total Daily Energy +# 08-33: Wi-Fi Credentials +# 34-35: Button Config select entity +# 36-37: Blue LED select entity +# 38-39: Red LED select entity +# 40-41: Debounce number entity +# 42-43: No HASS switch +# 44-55: Blue LED light entity +# 56-57: Scale Power +# 58-59: Scale Current +# 60-61: Scale Voltage +# 62-73: Red LED light entity |