Fix in Power.md
-rw-r--r-- | Documentation/Power.md | 2 |
1 files changed, 1 insertions, 1 deletions
diff --git a/Documentation/Power.md b/Documentation/Power.md index bb542b33..28c1f973 100644 --- a/Documentation/Power.md +++ b/Documentation/Power.md @@ -13,7 +13,7 @@ Combining these two gives the common equation, power is `Volts (V) squared / Res The resistance of the tip is fixed, ~7.5 ohms for the TS100/Pinecil and ~4.5 ohms for the TS80(P). This means that for both irons, the power delivered to the soldering tip is proportional to the voltage used, squared. -This is why the TS100 performs poorly when run off 12 V power supplies. +Therefore the TS100 performs poorly when run off 12 V power supplies. ## Output Control & Regulation |