aboutsummaryrefslogtreecommitdiffhomepage
diff options
context:
space:
mode:
authorKryštof Černý <[email protected]>2022-04-19 13:01:40 +0200
committerGitHub <[email protected]>2022-04-19 13:01:40 +0200
commitc68cedf8cfdff7e8270485ed73c4493a104b6eb0 (patch)
tree6041d2898c6e91ce8a44f43ae4301d1ba093e6a7
parentd808345b5bf355a5b611f3c5acf13ac7e3c27f5b (diff)
downloadIronOS-c68cedf8cfdff7e8270485ed73c4493a104b6eb0.tar.gz
IronOS-c68cedf8cfdff7e8270485ed73c4493a104b6eb0.zip
Fix in Power.md
-rw-r--r--Documentation/Power.md2
1 files changed, 1 insertions, 1 deletions
diff --git a/Documentation/Power.md b/Documentation/Power.md
index bb542b33..28c1f973 100644
--- a/Documentation/Power.md
+++ b/Documentation/Power.md
@@ -13,7 +13,7 @@ Combining these two gives the common equation, power is `Volts (V) squared / Res
The resistance of the tip is fixed, ~7.5 ohms for the TS100/Pinecil and ~4.5 ohms for the TS80(P).
This means that for both irons, the power delivered to the soldering tip is proportional to the voltage used, squared.
-This is why the TS100 performs poorly when run off 12 V power supplies.
+Therefore the TS100 performs poorly when run off 12 V power supplies.
## Output Control & Regulation