aboutsummaryrefslogtreecommitdiffhomepage
path: root/Documentation
diff options
context:
space:
mode:
authorKryštof Černý <[email protected]>2022-04-19 13:07:12 +0200
committerGitHub <[email protected]>2022-04-19 13:07:12 +0200
commit210f1a2ff044943dfb6d8c7c1ed3b91178d6fb6b (patch)
tree47378afab5e4b496597e199f9148b707ca618d9b /Documentation
parentc68cedf8cfdff7e8270485ed73c4493a104b6eb0 (diff)
downloadIronOS-210f1a2ff044943dfb6d8c7c1ed3b91178d6fb6b.tar.gz
IronOS-210f1a2ff044943dfb6d8c7c1ed3b91178d6fb6b.zip
Fix in Troubleshooting.md
Diffstat (limited to 'Documentation')
-rw-r--r--Documentation/Troubleshooting.md2
1 files changed, 1 insertions, 1 deletions
diff --git a/Documentation/Troubleshooting.md b/Documentation/Troubleshooting.md
index 688d89c3..58b4af29 100644
--- a/Documentation/Troubleshooting.md
+++ b/Documentation/Troubleshooting.md
@@ -17,7 +17,7 @@ If you can open up your iron, give it a good look at all the connection points,
If you are finding the tip is reading high; the first fields to check in the Debug menu are `RTip` and `CHan`.
-- `RTip` is the raw tip reading in μV; at cool this should be around 700-1000 for Larger tips and ~1500 for smaller tips (TS80's)
+- `RTip` is the raw tip reading in μV; at cool this should be around 700-1000 for larger tips and ~1500 for smaller tips (TS80's)
- `CHan` is the temperature of the temperature sensor on the PCB in degrees Celsius \* 10. So 29 °C ambient should read as 290
### RTip is out of spec